이전

CAMS

문의

KTMS-2500(Alarm Monitoring System)

The function of this system is to observe and control the conditions of all kinds of electrical or mechanical equipments at one place, which have been installed in various parts of ships, plants, buildings, etc. KTE's Alarm Monitoring & Control System, UNOSYS, brings more benefits to shipbuilders as well as ship owners.

THE MERIT OF KTMS-2500

FEATURE OF THE KTMS-2500
High reliability and stability
  • With fully dual Lonworks in local network and dual CPU structure in Local Signal Unit
Easy and concise operation
  • With user-friendly GUI (Graphic User Interface) environment
Smart system
  • Based on the accumulated experience and technology of KTE
Faithful customer oriented system
  • Which is tailored to vessel’s condition and maximizes customer’s satisfaction
Flexible and simple system expansion
  • With distributed, modular hardware

FEATURE OF THE KTMS-2500

FEATURE OF THE KTMS-2500
Self-diagnosis function applied
  • Watchdog timer
  • Power on self-test
  • Real time testit
Various communication methods available
  • RS-485/422, Lonworks, Ethernet
Bridge / Cabin Alarm Unit
Basic specifications
  • Power supply : 18 ~ 30VDC
  • Power consumption : MAX. 2A
  • Operating temperature : 0 ~ 70
  • Dimension(mm) : 240(w) X 165(l) X 40(h)
Main Functions
  • Remote alarm display / Repeat alarm
  • Watch mode change
  • Duty engineer / All engineer call
  • Independent fire alarm system
Distinctive Features
  • Detailed alarm information display with graphic LCD
  • The illumination of indicating lamps to be controlled by automatic dimmer function
  • Engineer Calling System can be carried out without additional H/W
  • Terminals for external buzzer stop input / buzzer output to be prepared
  • Various buzzer sound : 4 types
  • LonWorks / RS-485 communication support

SYSTEM CONSTRUCTION

SYSTEM CONSTRUCTION

Central Display Unit (CDU)

Central Display Unit (CDU)
Basic specifications
General specifications
  • Supply voltage : AC110 ~ 240V
  • Power consumption : 3.0A / 240V
  • Ambient storage temperature : 10 ~ 70
  • Ambient operational temperature : 10 ~ 70
Main board specifications
  • CPU : Pentium 4, 2.8Ghz or Higher
  • Main memory : 256MB or Higher
Output specifications
  • Monitor : 21", 19", 17", 15", etc. TFT LCD with mariner kit
Input specifications
  • Operating : Mouse & Keyboard
Main functions
  • Alarm, Group, Engineer select, Exhaust gas, Trend, View,
    Mimic display
  • System construction view
  • Parameter setting, Printing, Help display
  • Send alarm data to Bridge Alarm Unit & Cabin Alarm Unit
Data communication
  • Ethernet with other Central Display Unit
  • Lonworks / RS-485 with Bridge Alarm Unit & Cabin Alarm Unit
  • RS-232 / 422 / 485 with external interface
  • Redundancy for data communication (Lonworks)

Local Signal Unit (LSU)

Local Signal Unit - I
Local Signal Unit - I
Local Signal Unit - II
Local Signal Unit - II
Basic specifications
  • Power supply : 18 ~ 30VDC
  • Power consumption : MAX. 2A
  • Operating temperature : 0 ~ 70℃
Main functions
  • Dual CPU structure for reliable and failsafe operation
  • Fully dual LonWorks for system redundancy
    • Power on self-test / Watchdog timer
    • Remote diagnosis at Engine Control Room
    • Local indicating of each channel's alarm condition with LEDs

LSU Classification as Sensor / Instrument types

LSU AI (Analog Input)
  • 32 Channels analog signal input
    • 4 ~ 20mA / 10V / PT100 / Digital freely
  • selectable with DIP S/W
    • 16-Bit resolution of AD converter
LSU DI (Digital Input)
  • 32 Channels digital input
    • Each channel is isolated perfectly from power source
LSU DO (Digital Output)
  • 32 Channels digital output (dry contact)
LSU Multi (Multi-type Input / Output)
  • 16 Channels analog input / Digital input / Digital output
    • I/O Module can be changed freely in 4 channels

Extension Alarm Unit (EAU)

Extension Alarm Unit (EAU)
Basic Specifications
  • Power Supply : 18 ~ 30VDC
  • Power Consumption : Max. 2A
  • Operating Temperature : 0 ~ 70°C
  • Dimension(mm) : 240(w) X 165(l) X 40(h)
Main Functions
  • Common Functions
    • Remote alarm display / Repeat alarm
    • Independent fire alarm system
  • For Bridge Functions
    • Watch mode change
    • Duty engineer / All engineer call
  • For Cabin Functions
    • Duty call indication from E/R and W/H

Common Terminal Board (CTB)

Common Terminal Board (CTB)
Basic Specification
  • Power Supply : 18 ~ 30VDC
  • Power Consumption : Max. 1.5A
  • Operating Temperature : 0 ~ 70°C
  • Dimension(mm) : 190(w) X 80(l) X 35(h)
Main Functions & Features
  • Auxiliary I/O Unit for Central Display Unit
  • Buzzer Stop / Flickering Stop inputs
  • Buzzer Sound output
  • Exchangeable with the Local Comm. Server

Lon Gateway Unit (LGU)

Lon Gateway Unit (LGU)
Basic Specification
  • Power Supply : 18 ~ 30VDC
  • Power Consumption : Max. 1.5A
  • Operating Temperature : 0 ~ 70°C
  • Dimension(mm) : 130(w) X 80(l) X 35(h)
Main Functions & Features
  • Bidirectional Converter for serial & Can-bus
  • Communications to LonWorks
    • RS-232/422/485 & Can-bus selection by jumper pin
  • NMEA2000 Standard : Can-bus
    • Baud rate selectable by dip S/W
    • Flexible system expansion
    • Ease of system integration and maintenance by unified communication structure

LOCAL DISPLAY UNIT

Basic specifications
General specifications
  • Supply voltage : AC110 ~ 240V or DC24V
  • Power consumption : 3.0A / 240V or 2.0A / DC24V
  • Ambient storage temperature : 10 ~ 70
  • Ambient operational temperature : 10 ~ 70
General specifications
  • CPU : Celeron 566Mhz or Higher Main memory : 128MB or Higher
Output specifications
  • Monitor : 15", 12.1", 10.4" etc. TFT LCD
Input specifications
  • Operating : Touch panel
Main functions
  • Alarm, Group, Engineer select, Exhaust gas, Trend, View,
    Mimic display
  • System construction view
  • Parameter setting, Printing, Help display
Data communication
  • Redundancy for data communication (Lonworks)
  • Serial communication

BRIDGE / CABIN ALARM UNIT

Bridge Alarm UnitBridge Alarm Unit
Cabin Alarm UnitCabin Alarm Unit
Basic specifications
  • Power supply : 18 ~ 30VDC
  • Power consumption : MAX. 2A
  • Operating temperature : 0 ~ 70℃
  • Dimension(mm) : 240(w) X 165(l) X 40(h)
Main functions
  • Remote alarm display / Repeat alarm
  • Watch mode change
  • Duty engineer / All engineer call
  • Independent fire alarm system
Distinctive features
  • Detailed alarm information display with graphic LCD
  • The illumination of indicating lamps to be controlled by automatic dimmer function
  • Engineer Calling System can be carried out without additional H/W
  • Terminals for external buzzer stop input / buzzer output to be prepared
  • Various buzzer sound : 4 types
  • LonWorks / RS-485 communication support

ALARM DISPLAY/ALARM HISTORY DISPLAY

ALARM DISPLAY/ALARM HISTORY DISPLAY
  • Tag No., Description, Value, Date, Time display
  • Auto scroll function Data deleting & searching function

OPERATOR CONTROL PANEL(OCP) DISPLAY

OPERATOR CONTROL PANEL(OCP) DISPLAY
  • Operator interface display
  • Watch mode selection(Manned or Unmanned mode)
  • Duty engineer selection & calling Data printing function setting

EVENT DISPLAY

EVENT DISPLAY
  • Event list saving & display
  • Data deleting & searching function
  • Auto scroll function

GROUP DISPLAY I

GROUP DISPLAY I
  • Group No., Group name, Total channel No., Total alarm No.

GROUP DISPLAY II

GROUP DISPLAY II
  • Group point display
  • Tag No., Description, Function, Limit, Value, Status, Unit
  • Display detailed channel information
  • Auto scroll function

ENGINEER SELECT DISPLAY

ENGINEER SELECT DISPLAY
  • Display selected channel point List
  • Display max. 25 points per 1page
  • Display max. 20 pages
  • Inserting and deleting channel is freely
  • Display detailed channel information

EXHAUST GAS DISPLAY

EXHAUST GAS DISPLAY
  • Display analog data by trend graph
  • Tag No., Description, Function, Limit, Value, Status, Unit
  • Display max. 8 points per 1 page
  • Display max. 20 pages
  • Zoom in, Zoom out
  • Inserting and deleting channel is freely
  • Data storing for 168 hours Display detailed channel information

VIEW DISPLAY

VIEW DISPLAY
  • Display analog data by Bar / Meter gauge
  • Tag No., Description, Function, Limit, Value, Status, Unit
  • Display max. 8 points per 1 page
  • Display max. 20 pages
  • Inserting and deleting channel is freely Display detailed channel information

MIMIC DISPLAY

MIMIC DISPLAY
  • Serve 20 pages basically
  • Display max. 64 pages (Option) Mimic editor provided

SYSTEM DISPLAY

SYSTEM DISPLAY
  • Display system block diagram Display self diagnosis for local signal unit

SYSTEM DISPLAY

SYSTEM DISPLAY
  • Set time and date
  • Set password
  • Database view
  • Help language selection
  • Trend file copy (for KTMS-View)
  • Display ship information Printer information

HELP DISPLAY

HELP DISPLAY
  • System help information Guidance for using system

VALVE & PUMP CONTROL (Option)

VALVE & PUMP CONTROL (Option)
  • Valve On-Off control
  • Pump Run-Stop control
  • Pump St'by control

PMS DISPLAY & CONTROL(Option)

PMS DISPLAY & CONTROL(Option)
  • Bus voltage display
  • Bus frequency display
  • Bus power display
  • Generator status display
  • ACB Control
  • Generator engine control
  • Generator engine running mode selection

CCTV SYSTEM (Option)

CCTV SYSTEM (Option)
  • CCTV System provides complete oversight of all processes and areas on board including engine room to Central Display Unit, performing centralized and real-time monitoring.